Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Year range
1.
Eng. sanit. ambient ; 25(4): 573-581, jul.-ago. 2020. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1133808

ABSTRACT

RESUMO Os efluentes hospitalares sempre foram fonte de preocupação pela poluição microbiológica, mas somente com o aumento na detecção de antibióticos em águas de rios surgiu a necessidade de se avaliar o risco ambiental gerado pelos efluentes de hospitais. Nesse contexto, foi realizada uma avaliação de risco ambiental (ARA) para 19 antibióticos utilizados em um serviço de internamento pediátrico hospitalar pelo período de 36 meses (junho de 2013 a maio de 2016). O principal objetivo deste estudo foi estimar o risco ambiental associado ao padrão de uso dos antibióticos selecionados lançados na rede de esgoto. A ferramenta utilizada para a avaliação de risco foi a concentração ambiental prevista (CAP), Fase I e Fase II (EMeA, 2006). Foram levantados os dados de população, dispensação e administração dos antibióticos para o cálculo da CAP, e valores de referência da concentração ambiental prevista em que não se observam efeitos (CAPNE) foram obtidos de fontes na literatura. O quociente de risco (QR) usado para caracterizar o risco foi obtido por meio da razão CAP/CAPNE. Apenas quatro antibióticos apresentaram QR abaixo do limiar de nível alto (QR < 1), enquanto os outros 15 antibióticos apresentaram valores de QR considerados de alto potencial de dano ambiental, tendo-se verificado os valores mais elevados para ceftriaxona, piperaciclina, tazobactam, ciprofloxacino, vancomicina e oxacilina. Os resultados evidenciaram que existe risco substancial de danos ambientais associado à descarga dessas substâncias no efluente, consistindo em preocupação ambiental significativa com relação ao padrão de consumo de antibióticos no setor de internamento pediátrico hospitalar.


ABSTRACT Hospital effluents have always been a source of concern for microbiological pollution, but only with the increase in the detection of antibiotics in river waters has there been a need to evaluate the environmental risk generated by hospital effluents. In this context, an environmental risk assessment (ERA) was carried out for 19 antibiotics used in a pediatric inpatient hospital ward for a period of 36 months (June 2013 to May 2016). The main objective of this study was to estimate the environmental risk associated with the use of the selected antibiotics released into the sewage system. The tool used for risk assessment was the Predicted Environmental Concentration (PEC) Phase I and Phase II (EMeA, 2006). Data on population, dispensation, and administration of antibiotics were collected for the calculation of the PEC, reference values of the Predicted no Effect Concentration (PNEC), were obtained from sources in the literature. The Risk Characterization Ratio (RCR), used to characterize the risk, was obtained through the PEC/PNEC ratio. Only four antibiotics presented values below the high-level threshold (RCR < 1), the other fifteen antibiotics presented RCR values corresponding to a high potential for environmental damage, with the highest values being observed for ceftriaxone, piperacycline, tazobactam, ciprofloxacin, vancomycin, and oxacillin. The results showed that there is substantial risk of environmental damage associated with the discharge of these substances into the effluent, representing a significant environmental concern regarding the pattern of antibiotic consumption in hospital pediatric wards.

2.
J. bras. patol. med. lab ; 48(1): 15-20, fev. 2012. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-617012

ABSTRACT

INTRODUÇÃO: O aumento de tecnologia e equipamentos automatizados em laboratórios de análises clínicas permitiu ampliar significativamente a capacidade de análises e processamento de informações. Entretanto, aumentou também na mesma proporção a utilização de reagentes químicos nas análises, gerando resíduos que, se descartados de forma incorreta, causam sérios danos ao meio ambiente. OBJETIVO: avaliar a informação e a conscientização dos profissionais de laboratórios de análises clínicas em relação a possíveis danos ambientais causados pelos resíduos químicos produzidos, forma de descarte adotada e interesse em receber informações relacionadas. MATERIAL E MÉTODOS: Foram realizadas entrevistas, estruturadas em questionário, para obter a quantidade de análises hematológicas realizadas na cidade de Curitiba/PR, o modo de descarte dos resíduos gerados pelos equipamentos automatizados e, também, para inferir sobre o conhecimento dos profissionais quanto à formulação das soluções, à forma recomendada de descarte e ao potencial para causar danos ao meio ambiente. RESULTADOS E CONCLUSÃO: A maioria (80 por cento) dos profissionais de laboratórios de análises clínicas acredita ser responsável pelo resíduo produzido, no entanto não possui conhecimento sobre a questão. Esse desconhecimento propicia práticas inadequadas em 47 por cento dos laboratórios pesquisados, que descartam o resíduo diretamente na rede coletora de esgotos. Para evitar a contaminação biológica, 20 por cento dos laboratórios tratam os resíduos com hipoclorito antes de descartá-los na rede coletora de esgoto, e apenas 12 por cento deles possuem tratamento para efluentes, porém esse tipo de procedimento realizado é desconhecido.


INTRODUCTION: The widespread use of technology and automated equipment in clinical laboratories has allowed to expand analysis capacity and information processing significantly. However, it has also augmented the use of chemical reagents in analyses, generating waste that, if improperly disposed, may cause serious environmental damage. OBJECTIVES: To evaluate the knowledge and awareness of clinical laboratory professionals as to the potential environmental damage caused by chemical waste, adopted forms of disposal, and interest in receiving related information. METHODS: Interviews were conducted in a structured questionnaire in order to assess the total number of blood tests performed in the city of Curitiba and the forms of waste disposal generated by automated equipment. They were also developed to infer professionals' knowledge regarding solution development, recommended ways of disposal, and potential environmental hazard. RESULTS AND CONCLUSION: The vast majority (80 percent) of professionals in clinical laboratories believes to be responsible for the produced waste, but has no knowledge on the issue. This unawareness generates inadequate practices in 47 percent of surveyed laboratories, which discard waste directly into the sewer system. In order to avoid biological contamination, 20 percent of the laboratories treat their waste with sodium hypochlorite before disposal into the sewer system, and only 12 percent have sewage treatment, though its type is unknown.

3.
Hig. aliment ; 25(196/197): 138-141, maio-jun. 2011. tab
Article in Portuguese | LILACS | ID: lil-616615

ABSTRACT

A carne devido a sua composição pode favorecer o desenvolvimento de diversas bactérias. O presente estudo teve como objetivo avaliar de 2003 a 2008 diversos tipos de salames provenientes de várias cidades do Paraná. As cidades foram agrupadas por regiões e três micro-organismos foram analisados: Staphylococcus coagulase positiva, coliformes a 45°C e Salmonella sp. Observou-se pela análise, condenação por coliformes na maioria dos casos (47,22%) e a região Sudoeste foi a que apresentou maiores problemas (86,11%)


Subject(s)
Food Contamination , Food Samples , Meat Products/microbiology , Brazil , Coliforms , Salmonella/isolation & purification , Staphylococcus/isolation & purification
4.
Braz. arch. biol. technol ; 52(spe): 143-150, Nov. 2009. ilus, graf, tab
Article in English | LILACS | ID: lil-539860

ABSTRACT

Starch nutritional fractions as well as thermal properties and other analysis are essential for food and industrial application. Cassava bagasse is an important agro-industrial residue and its starch content was evaluated using two alternative methods. Thermal characterization and microscopy analyses helped to understand how hydrolysis digests starchy fraction of cassava bagasse. The melting point of cassava starch occurred at 169.2ºC. Regarding TG analyses, after moisture content, there were observed two main mass losses for all samples. Results suggest hydrolysis carried out using enzyme is less effective in order to convert total starch content in cassava bagasse. However, using sulfuric acid, fibers are affected by analyses conditions.


As frações nutricionais bem como as propriedades térmicas e outras análises são essenciais para a indústria de alimentos e suas aplicações O bagaço de mandioca é um importante resíduo agroindustrial e seu teor de amido foi avaliado por dois métodos alternativos. A caracterização por análise térmica e microscopia ajudou na compreensão de como a hidrólise digere a fração amilácea do bagaço de mandioca, O ponto de fusão foi de 170ºC, a análise termogravimétrica (TG) mostrou após a perda de umidade do material, duas principais perdas de massa em todas as amostras analisadas. Os resultados sugerem que a hidrólise enzimática é menos eficiente na conversão total de amido no bagaço de mandioca. No entanto, o uso de ácido sulfúrico degradou até mesmo a parcela fibrosa do material, afetando as condições de análise.

5.
Braz. arch. biol. technol ; 52(4): 855-862, July/Aug. 2009. tab, ilus
Article in English | LILACS | ID: lil-525606

ABSTRACT

The aim of this study was to detect and quantify the main residual monomers released from composites, using high performance liquid chromatography (HPLC). Discs were made with dental composites (Herculite XRV, Tetric Ceram and Filtek Z250) and immersed in deionized water at 37ºC for 28 days, with water changes in 1, 7, 14 and 21 days. The mean concentration of residual monomers were subject to the Kruskal-Wallis test (p<0.05). Tetric Ceram exhibited significantly higher concentrations of leached monomers. Bis-GMA was the monomer released in lower concentrations for all the materials. There was no statistical difference between the amounts of TEGDMA and UDMA. Most of the monomers demonstrated maximal concentration at the 7-day period. The HPLC analysis identified Bis-GMA, TEGDMA and UDMA in detectable quantities for all the tested composites.


A liberação de monômeros residuais pode afetar o comportamento clínico e a biocompatibilidade dos materiais resinosos. O objetivo deste estudo foi detectar e quantificar os principais monômeros residuais liberados de resinas compostas, usando cromatografia líquida de alta performance (HPLC). Discos foram construídos de resinas compostas de uso odontológico (Herculite XRV, Tetric Ceram and Filtek Z250) e imersos em água deionizada a 37ºC durante 28 dias, com mudanças de água em 24 horas, 7, 14 e 21 dias. As concentrações médias dos monômeros residuais foram submetidas ao teste de Kruskal-Wallis (p<0,05). Tetric Ceram apresentou as maiores concentrações de monômeros lixiviados. Bis-GMA foi o monômero liberado em menores concentrações para todos os materiais. Não houve diferença estatística significante entre TEGDMA e UDMA. A maioria dos monômeros demonstrou máxima concentração no período de 7 dias. A análise por meio de HPLC identificou Bis-GMA, TEGDMA e UDMA em quantidades detectáveis para todas as resinas compostas testadas.

SELECTION OF CITATIONS
SEARCH DETAIL